What's new in version 3.2
Version 3.2.129719.0 of COSMO Unique Device Identification adds the export of EU UDI-DIs and Basic UDI-DIs for EUDAMED submission, and the Swedish language. Users can now add their own UDI Size Types and UDI Measure Units.
Important
On-Premises customers coming from versions 2.0 or 2.1 and aiming for version 3.0 or higher must first upgrade to version 2.2 or 2.3 to get their data adjusted.
The final upgrade to version 3.x will require a publish with ForceSync. Refer to the Microsoft Dynamics 365 Business Central Help for more information about Upgrading an App by Using ForceSync.
Features and enhancements
The following features are included in this release:
Pull Request | Description |
---|---|
PR6704 | Disabled app based on UDI Base granule status in License Overview. |
PR6705, PR6876, PR6896 | Refactored code. |
PR6728, PR6729, PR6745 | Introduced UDI-DI Additional Descriptions. |
PR6763 | Redesigned EMDN Codes. |
PR6775 | Added Item Attributes page to Role Center. |
PR6781 | Replaced Basic UDI-DI "Medicinal Purpose" field with new table. |
PR6785, PR6857, PR6858, PR6859, PR6897, PR6935, PR6984 | Added XML file export to EUDAMED. |
PR6803 | Made UDI Size Types and UDI Measure Units customizable. |
PR6869 | Added event OnBeforePrintLabelDataEntriesWithReports. |
Bugfixes
This release fixes the following issues found in the previous version of the app:
Pull Request | Description |
---|---|
PR6694 | Refactored check for updating UDI-DIs from Basic UDI-DIs. |
PR6699 | Removed license check on checking MDN format. |
PR6703 | Ensured "Is English" in a UDI Language can be set only once. |
PR6730 | Showed "Variant Code" field on UDI-DI Substances pages. |
PR6773 | Added Basic UDI-DI status check on updating Certificates or Clinical Investigations. |
PR6774 | Added UDI filter on Attribute lookup for Clinical Sizes. |
PR6817 | Added Basic UDI-DI status check on EU UDI-DI release. |
PR6939 | Fixed FDA export of clinical sizes. |
PR6940 | Fixed text or translation related issues. |
Hotfixes
The following hotfixes are included in this release:
Hotfix No. | Pull Request | Description |
---|---|---|
N/A | N/A | N/A |
Removed or deprecated features
Removed obsolete controls, objects and methods:
Pull Request | Description |
---|---|
PR6803, PR6785, PR6781, PR6763 | Obsoleted code. |
Deprecation code list:
Description | Obsolete State | Obsolete Reason |
---|---|---|
Table "CCS UDI Size Type" | Pending | Replaced with the "CCS UDI Size Type 2" table. |
Page "CCS UDI Size Types" | Pending | Replaced with the "CCS UDI Size Types 2" page. |
Table "CCS UDI Unit of Measure" | Pending | Replaced with the "CCS UDI Measure Unit" table. |
Page "CCS UDI Units of Measure" | Pending | Replaced with the "CCS UDI Measure Units" page. |
Page "CCS UDI Manager Role Center", action SizeTypes | Pending | Replaced with the SizeTypes2 action. |
Page "CCS UDI Manager Role Center", action UnitsOfMeasure | Pending | Replaced with the MeasureUnits action. |
Table "CCS UDI Basic UDI-DI", field "Version No." | Pending | Replaced with the "Version No. 2" field. |
Table "CCS UDI Basic UDI-DI", field "Medicinal Purpose" | Pending | Replaced with the "CCS UDI BUDI-DI Med. Purpose" table. |
Page "CCS UDI Basic UDI-DI Card", field "Medicinal Purpose" | Pending | Replaced with the "No. of Medical Purposes" field. |
Page "CCS UDI BUDI Details FactBox", field "Medicinal Purpose" | Pending | Replaced with the "No. of Medical Purposes" field. |
Table "CCS UDI EU MDN" | Pending | Replaced with the "CCS UDI EU EMDN" table. |
Page "CCS UDI EU MDN Codes" | Pending | Replaced with the "CCS UDI EU EMDN Codes" page. |
Table "CCS UDI EU UDI-DI", field "Version No." | Pending | Replaced with the "Version No. 2" field. |
Table "CCS UDI EU UDI-DI", field "MDN Code" | Pending | Replaced with the "CCS UDI DI EMDN Code" table. |
Table "CCS UDI EU UDI-DI", field "Not for EU" | Pending | Replaced with the new Device Status value "NOT_INTENDED_FOR_EU_MARKET. |
Table "CCS UDI EU UDI-DI", field Substatus | Pending | Unused. Will be removed in a future release. |
Table "CCS UDI EU UDI-DI", field "Substatus Date" | Pending | Unused. Will be removed in a future release. |
Table "CCS UDI EU UDI-DI", field "Recall Scope" | Pending | Unused. Will be removed in a future release. |
Page "CCS UDI EU UDI-DI Card", field "MDN Code" | Pending | Replaced with the "No. of EMDN Codes" field. |
Page "CCS UDI EU UDI-DI Card", field group Regulatory_NotSPP | Pending | Replaced with the new Device Status value "NOT_INTENDED_FOR_EU_MARKET. |
Page "CCS UDI EU UDI-DI Card", field "Not for EU" | Pending | Replaced with the new Device Status value "NOT_INTENDED_FOR_EU_MARKET. |
Page "CCS UDI EU UDI-DI Card", field group Regulatory_ForEU | Pending | Replaced with the new Device Status value "NOT_INTENDED_FOR_EU_MARKET. |
Page "CCS UDI EU UDI-DI Card", field group SafetyInfo_Substatus | Pending | Unused. Will be removed in a future release. |
Page "CCS UDI EU UDI-DI Card", field Substatus | Pending | Unused. Will be removed in a future release. |
Page "CCS UDI EU UDI-DI Card", field "Substatus Date" | Pending | Unused. Will be removed in a future release. |
Page "CCS UDI EU UDI-DI Card", field group SafetyInfo_RecallScope | Pending | Unused. Will be removed in a future release. |
Page "CCS UDI EU UDI-DI Card", field "Recall Scope" | Pending | Unused. Will be removed in a future release. |
Enum "CCS UDI EU Device Substatus" | Pending | Unused. Might be removed in a future release. |
Technical specifications
Details | Version |
---|---|
Requires Microsoft Base Application | 19.0.0.0 |
Requires COSMO Licensing app | 2.1.0.0 |
Feedback
Submit feedback for this page .